TOOLS for Zinsser Automated Platforms
Zinsser automated liquid handling platforms are unique on the market
because of the selection of high-performance tools that can be installed
on the deck. The ability to select from this list of tools allows the
user to configure a system that will fully automate the required application,
whether it requires liquid handling, powder handling, weighing, heating,
cooling, vortexing, pressurization, vacuum, or almost anything that can
be imagined.
This page provides a complete listing of available tools for Zinsser
system. This list is always growing, and if you have an idea that is
not here, please contact us and we can likely accomplish it.
(Click on thumbnails for to open a larger image in a new window)
Back to Top
|
|
|
|
Stainless steel fixed pipetting tips for liquid handling. Variable
span allows access to any kind of labware. |
Disposable pipette tips for liquid handling where zero carryover
is required. |
Deck station for removal of disposable tips, with chute for waste
storage of used tips. |
Multichannel probes with 2 or 3 channels allow distribution of
various combinations of liquid, gas, and vacuum. |
|
|
|
|
Heated probe. Liquid flows through heated coil built in to probe,
prevents precipitation of saturated solutions. |
3 channel probe with filter on inner channel allows simultaneous
delivery of liquid with vacuum; used for rinsing particles. |
Ceramic probe. |
Different probes can even be configured for the system. Shown
here are blunt and angled fixed probes, a disposable tip, and a
powder dispensing tip. |
|
|
|
4 different powder dispensing tips are available,
allowing pickup and dispense of fixed amounts, or with manual or
automatic volume variability. |
|
|
Back to Top
|
|
|
|
Reading of plate barcode using gripper and deck-mounted
scanner. |
Reading of vial barcode using gripper and deck-mounted scanner. |
Reading of vial barcode using gripper and deck-mounted scanner. |
|
Back to Top
|
|
|
|
Calli automated platform with integrated Sartorius Genius balance.
The integration includes automatic open and close of the balance
door. The Calli gripper places and removes labware to the balance. |
Gripper places a vial to be weighed directly on the balance pan. |
Custom rack made for balance allows placement of multiple vials
on the balance. |
Custom-made weigh station integrated directly on the Zinsser deck
and to the Zinsser WinLissy software. |
Back to Top
|
|
|
|
Deck-mounted high-speed vortexer. Includes automatic clamps to
secure labware, and can be integrated with heating (150 deg C or
250 deg C) or cooling via recirculating water bath. |
Deck-mounted vortexer with clamped-down reaction block. |
Deck-mounted vortexer with cooling via recirculation water bath. |
The Zinsser vortexers have been specially designed with a movement
pattern that ensures thorough mixing of liquid rather than just moving
it around. |
|
|
|
|
Powder reservoir mounted on automatic shaker. The shaker helps
ensure even powder distribution prior to dispensing. |
Deck mounted sonicator provides enhanced mixing for dissolution
of solids. |
External vortexing station allows offline vortexi.ng of blocks for long-term synthesis reactions |
Single tube vortexer mounted on deck. Gripper can move vials or tubes to the vortexer. |
|
|
|
|
Heavyduty vortexer supports rack larget than the standard microplate footprint, for example 40 x 20 ml vials. Holds up to 2.5 kg. |
Stirring tool for powder reservoir ensures even distribution of powder before aspiration for maximum reproducibility. |
|
|
Back to Top
|
|
|
|
Deck-mounted high-speed vortexer. Includes automatic clamps to
secure labware, and can be integrated with heating (150 deg C or
250 deg C) or cooling via recirculating water bath. |
Deck-mounted vortexer with cooling via recirculation water bath. |
Microwave from CEM interface to the platform. The gripper move
tubes directly into the microwave for rapid heating. |
Deck-mounted cooling plate for solvent reservoir and two microplates. |
Back to Top
|
|
|
|
Deck-mounted vacuum station. The lid can be removed by the gripper
and parked, allowing access for SPE blocks or cartridge racks. The
vacuum is software controlled. |
A receiving plate is placed in the vacuum box, reader for the
3M SPE block with lid to be placed using the gripper. |
Closeup of SPE cartridges mounted on block, using gas probes
for monitored positive pressurization. Vacuum and/or positive pressure
can be used. |
3 channel probe with filter on inner channel allows simultaneous
delivery of liquid with vacuum; used for rinsing particles. |
Back to Top
|
|
|
|
Stainless steel fixed pipetting tips for liquid handling. Variable
span allows access to any kind of labware. |
Disposable pipette tips for liquid handling where zero carryover
is required. |
Plate Lifter for retrieving maximum amount of sample from a plate
with minimum loss. Useful for CACO2 applications; allows pipetting
from plate without touching cell layer on the bottom. |
Programmable 6-way valve allows switching to 6 different solvents.
Any solvent can be sent to any probe for solvent delivery to labware. |
|
|
|
|
4-channel peristaltic pump for bulk liquid delivery |
|
|
|
Back to Top
|
|
|
|
Redi-Fix tip for aspiration and dispensing powder. This tip
has a fixed volume; it will pick up the amount amount each time
(45 microliter version shown). |
Fixed tips are available in different volumes. THe user can easily
interchange them. |
Redi Pick-Fix tips are also fixed volumes, but can be automatically
interchanged by the system. |
Varedi fixed tip allows user to "dial in" a powder pipetting volume. |
|
|
|
|
Varix tip includes software module for programmable volumes. |
5 steps of powder pipetting. 1. Shake the reservoir for even distribution.
2. Aspirate powder using vacuum. 3. Strip excess particles from outside
of tool. 4. Distribute powder to labware. 5. Clean the tip. |
|
|
Back to Top
|
|
|
|
The platform can be configured for gas delivery for a variety of
purposes. Adjustable pressure with readout gauges on left side of
instrument. |
The deck-mounted vortexer is configured with gas ports that can
directly connect to a reaction manifold for sparging. |
Exploded view of the reactor assembly showing the path of inert
gas. |
Multichannel probes allow gas to be delivered into vials for pressurization,
for inert environment, or even at the same time as liquid for dynamic
washing. |
|
|
|
|
Argon box installed on the deck allows selected labware to be maintained
in an inert environment. |
96 channel drying manifold is connected to nitrogen supply and
can be moved over microplates by the gripper for sample drydown. |
|
|
Back to Top
|
|
|
|
Deck-mounted vacuum station. The lid can be removed by the gripper
and parked, allowing access for SPE blocks or cartridge racks. The
vacuum is software controlled. |
Multichannel probes allow vacuum to be supplied into vials
or labware to remove contents. |
Sample Concentrator. Manifold with RS232 controlled vacuum station
with water cooled chemical trap, 24-channel head, parkstation for
evaporation head, pneumatic valves, software to control vacuum.
The gripper moves the lid to the labware on the vortexer. |
|
Back to Top
|
|
|
|
Variable probes allow access to all types and styles of vials and
tubes as well as microplates. |
Virtually any combination of racks for vials and tubes can be configured
on the deck. |
Different size reservoirs for powders are available. |
The deck can be configured with shallow well microplates, deep
well microplates, and tubes, in any required combination. |
|
|
|
|
Labware can be heated or cooled on the deck. |
Desyre reactor assemblies for synthesis reactions are available
in different sizes; fitting within the microplate footprint. |
The Desyre reactors can have the lid automatically removed and
returned using the robot gripper. |
Microtube downhold with pneumatic clamping for piercing of microtubes. |
|
|
|
|
Plate Lifter for retrieving maximum amount of sample from a plate
with minimum loss. Useful for CACO2 applications; allows pipetting
from plate without touching cell layer on the bottom. |
TLC plates configured for TLC spotting in the microplate footprint. |
Special reactor for Crissy salt prescreening system.
The reactor consists of an
aluminum carrier with 96 PTFE-inserts
(reusable and cleanable in an ultra sonic bath)
and adjustable bases with a glass disc on top.
|
Filtration labware can be automatically placed in a vacuum box
using the robotic gripper. |
|
|
|
|
Automatic capper/decapper configured on the deck. The gripper brings
vials for automated capping operations. |
CEM microwave tube automatically delivered to microwave device. |
Automated capper and decapper tools for CEM microwave tools. |
|
Back to Top
|
|
|
|
24 position rack for 3 ml SPE cartridges. |
24 position rack for 1 ml SPE cartridges. |
96 position tube/vial rack. |
192 position tube/vial rack. |
|
|
|
|
Customer-supplied rack. Virtually any desired rack can be engineered
to fit on the deck. |
Plate stack allows multiple shallow well or deep well plates to
be stacked on the deck and accessed by the robotic gripper to increase
capacity. |
Random access plate stacks allows multiple shallow well or deep
well plates to be stacked on the deck and accessed by the robotic
gripper to increase capacity. |
Special rack to hold TLC media for automated spotting. |
Back to Top
|
|
|
|
The robotic gripper can pick up and deliver plates, tubes, and
special tools for delivery to various devices mounted on the deck. |
The gripper can pick up and carry an entire reaction block with
lid for movement to a heater/cooler/vortexer. |
The gripper can also pick up a variety of special tools, such as
this powder dispensing tool. |
Gripper picking up a single microwave tube using a custom tool.
Multiple tools can be parked on the deck for access by the gripper,
allowing different tasks to easily be performed with a single gripper
configuration. |
Back to Top |